GXC100S-NG

PowerLink Engine Gas CHP with high quality and performance

Download Specs
GXC100S-NG
GXC100S-NG
下载 (3)

Mixer

Mixer to adjust the ratio of air and gas

GXC100S-NG gallery

Gas Valve Group

Gas valve group, used for pressure regulation, filtration, balancing, safety protection

GXC100S-NG (8)_proc
Gas valve group, used for pressure regulation, filtration, balancing, safety protection_proc
1 1

Oil Filling Filter System

The automatic lubricating oil filling filter system can filter impurities in the engine, prevent oil deterioration, and minimize

GXC100S-NG (3)_proc

Control Cabinet

The control cabinet of the GXC100S-NG unit is arranged on the side of the box to save space

青浦现代农业园区沼气热电联产项目03_proc
The control cabinet of the GXC100S-NG unit is arranged on the side of the box to save space_proc

 

Spare Parts List - GXC100S-NG

Description Part Number Number Model Position
Long block engine 1000256737 1 GX7S-LE02 Genset
Alternator 1000077842 1 LSA44.3M8 Genset
Pressure temerature sensor 1000266087 1 Electric control
Phase sensor 1000077124 1 Electric control
Temerature sensor 1000266081 1 Electric control
Knock sensor 1000266093 1 Electric control
Speed sensor 1000140902 1 Electric control
Pressure temerature sensor 1000373066 1 Electric control
Wide band oxygen sensor 1000266088 1 Electric control
Temerature sensor 1000242561 5 Electric control
Pressure sensor 1000242558 5 Electric control
Jacket water pump 1000348876 2 Engine
Intercooler water pump 1000348872 1 Engine
Turbocharger 1000241489 1 Engine
Mixer 1000266138 1 Engine
Oil filter element 1000061072 2 Engine
Air/ oil separator elemnet 1000197165 2 Engine
Gas filter element 1 Engine
Air filter element 1000197165 1 Engine
Sparking plug 1000209708 2 Engine
Exhaust pipe weldment 1000356966 1 Engine
Exhaust pipe weldment 1000356962 1 Engine
Turbocharger 1000241489 1 Engine
Cylinder sleeve cushion ring 6 Engine
Cylinder sleeve cushion ring 6 Engine
Cylinder sleeve cushion ring 6 Engine
Cylinder head assembly 1 Engine
Cylinder head bolt 6 Engine
Cylinder head bolt 20 Engine
Cylinder head gasket 1 Engine
Piston 6 Engine
Piston ring 6 Engine
Oil pump 1000122503 1 Engine
Motor 1000247006 1 Engine
Relay 1000113053 1 Electric control
Relay 1000283231 1 Electric control
Relay 1000205455 12 Electric control
Relay 1000205456 1 Electric control
Control module 1000266459 1 Electric control
Control module 1000242656 12 Electric control
Control module 1000283713 1 Electric control
Control module 1000283339 2 Electric control
Control module 1000224683 2 Electric control
Control module 1000224684 1 Electric control
Control module 1000230641 2 Electric control
Control module 1000233282 1 Electric control
Control module 1000327245 1 Electric control
Control module 1000242546 1 Electric control
Float charger 1000327902 1 Electric control
Float charger 1000283306 1 Electric control
 GXC100S-NG Gas Cogeneration units Powered by PowerLink player

GXC100S-NG Gas Cogeneration units Powered by PowerLink

PowerLink Gas Generator and Gas cogeneration 10-2000KW player

PowerLink Gas Generator and Gas cogeneration 10-2000KW

Fully tested before Delivery to the Customer Site player

Fully tested before Delivery to the Customer Site

Mini Combined Heat and Power Solution player

Mini Combined Heat and Power Solution

下载 (3)

Mixer

Mixer to adjust the ratio of air and gas

GXC100S-NG gallery

Gas Valve Group

Gas valve group, used for pressure regulation, filtration, balancing, safety protection

GXC100S-NG (8)_proc
Gas valve group, used for pressure regulation, filtration, balancing, safety protection_proc
1 1

Oil Filling Filter System

The automatic lubricating oil filling filter system can filter impurities in the engine, prevent oil deterioration, and minimize

GXC100S-NG (3)_proc

Control Cabinet

The control cabinet of the GXC100S-NG unit is arranged on the side of the box to save space

青浦现代农业园区沼气热电联产项目03_proc
The control cabinet of the GXC100S-NG unit is arranged on the side of the box to save space_proc

 

A cogeneration system is both flexible and reliable, because of its efficient use of energy, industrial-scale cogeneration is more economical and environmentally attractive than conventional fossil fuel power plants.

Inventory List

No. Product No. Model Job No. Quantity Unit Type Structure Engine Model Alternator Model Control Specs
1 1000244011 GR12S-NG PLS1187/1 1 Genset Soundproof GR1.8E01 ECP28-S/4 MRS specs
2 1000244012 GR16S-NG PLS1187/2 1 Genset Soundproof GR2.5E01 ECP28-M/4 MRS specs
3 1000244014 GR28S-NG PLS1188/1 1 Genset Soundproof GR3.8E01 ECO32-2S/4 MRS specs
4 1000258530 GR16S-LPG PLS1207/6 1 Genset Soundproof GR2.5 E01 ECP28-M/4 PLC220 specs
5 1000028221 GR20S-LPG PLS1406/2 1 Genset Soundproof WG2503-N-PWL-1 LSA42.3VS1 XC762 specs
6 1000028222 GR30S-NG PLS1406/3 1 Genset Soundproof WG3800-N-C-CHN-1 LSA42.3S5 XC762 specs
7 1000026105 GXC50S-BG PLS1354/1 1 CHP Soundproof GX5S-LE02C PL2D PCC300 specs
8 1000026105 GXC50S-BG PLS1354/2 1 CHP Soundproof GX5S-LE02C PL2D PCC300 specs
9 1000026105 GXC50S-BG PLS1354/3 1 CHP Soundproof GX5S-LE02C PL2D PCC300 specs
10 1000026105 GXC50S-BG PLS1354/4 1 CHP Soundproof GX5S-LE02C PL2D PCC300 specs
11 1000026107 GXC150S-BG PLS1326/1 1 CHP Soundproof GX10T-LE02C LSA46.3S3 PCC300 specs
12 1000026107 GXC150S-BG PLS1326/2 1 CHP Soundproof GX10T-LE02C LSA46.3S3 PCC300 specs
13 1000026107 GXC150S-BG PLS1326/3 1 CHP Soundproof GX10T-LE02C LSA46.3S3 PCC300 specs
14 1000028195 GXE250MC-NG PLS1397/2 1 Genset Mini Container GX13K-LE02G PL4LS GCC742 specs
15 1000027454 CG520C-BG PG2109/3 1 CHP Container E 3262 LE202 LSA49.3M6 PCC300 specs
16 1000028235 GXE150S-BG PG2251/19 1 Genset Soundproof GX10T-LE02G PL3F GCC742 specs
17 1000028235 GXE150S-BG PG2251/20 1 Genset Soundproof GX10T-LE02G PL3F GCC742 specs
18 1000028235 GXE150S-BG PG2251/21 1 Genset Soundproof GX10T-LE02G PL3F GCC742 specs
19 1000028231 GXE250S-BG PG2251/24 1 Genset Soundproof GX13K-LE01G BG PL4LS GCC742 specs
20 1000352001 GXE100-BG PLS1334/2 1 Gas Genset Open GX7S-LE02 PL3DS GCC742 specs
21 1000028188 GXC110S-6BG PG2216/2 1 CHP Soundproof GX7S-LE02 PL3DS GCC742 specs
22 1000028229 TCG800-NG PLS1405/1 1 CHP Open TCG3016V16 LSA50.2M6 PCC300 specs
23 1000244004 GXE180-NG PLS1198/4 1 Genset Open 50Hz-3PH GX11F-LE02 LSA46.2L6 specs
24 1000258609 GSC25S PLS1218/3 1 MCHP Soundproof 50Hz-3PH 4Z ECP28-VL/4 specs
25 1000286167 GXC200C-BG PLS1266/3 1 CHP Container GX12T-LE02C PL3H PCC300 specs
26 1000027473 GXC200C-BG PLS1339/1 1 CHP Container GX12T-LE02C PL4MS PCC300 specs
27 1000027320 GXE350S-6BG PG2041/4 1 Genset Soundproof GX22D-LE02 LSA47.2S5 GCC742 specs
28 1000028177 GXE100S-BG PG2196/1 1 Genset Soundproof GX7S-LE02 PL3DS GCC742 specs
29 1000286229 GXE260C-6BG PG2086/1 1 Genset Container GX13K-LE02 NG PL4M GCC742 specs
30 1000434009 GRS30S-LPG PLS1444/1 1 Genset Soundproof 50Hz-3PH GR3.0 LE01L PL2B specs
31 1000037041 GXE350-NG PLS1264 1 Genset Open 1500/50 GX20T-LE02 S5L1D-C4 specs
32 1000352466 ACG20S PLS1395/1 1 MCHP Soundproof 50Hz-3PH 4Y specs
33 1000025868 CG500DS-BG PLS1252/2 1 CHP Soundproof 50Hz-3PH TBG-616V12K specs
34 1000037064 ACG30S-6NG PLS1463/1 1 MCHP Soundproof 1800/60 60HZ/3PH PCC300M specs
35 1000037065 ACG50S-6NG PLS1463/2 1 MCHP Soundproof 1800/60 60HZ/3PH PCC300M specs
36 1000037040 GXE250-NG PLS1444/4 1 Genset Open 1500/50 50Hz-3PH PCC300 specs

GAS COGENERATION

Our GXC100S-NG Natural Gas CHP sets are a series of energy-saving products with a power range of 10KW – 2000KW and are fitted with a selection of different engines, which allow our engines to meet the needs of different types of applications. Our generators are fitted with a PLM (full life cycle management) system which can generate reports and display System data management and will show you the value of investment we have applied to these systems. Stable operation and quick recovery of investment are targets that our design and manufacturing department works for. And we did it.

From materials to manufacturing, we know the significance of stability and durability for investors. From materials, chemical calculation, parts technology, fluid calculation, heat exchange technology, mechanical design, automatic control, and Internet of things technology, the application of these professional technologies is the basic condition for the stable operation of biogas cogeneration systems.

GAS COGENERATION

PARTNERSHIP ENTRANCE

Interested to be our partner to provide energy to the world